UNIMAG 5600 AC

BASIC DESCRIPTION: 
  • clamping length between the poles 5600 mm, stroke of pneumatic valve 2x 50 mm, mechanically poles adjustment
  • weight of tested parts up to 2000 kg
  • rollers for manual rotation
  • PLC control
  • by touchscreen setting of testing parameter
  • current (circulary) AC magnetization 4000 A r.m.s (effective value), TRMS measurement
  • manually movable AC coil 320 mm, exchangeable for 620 mm
  • signalling deviation ± 10% of preseted values for both circuit
  • timers for magnetisation and wetting 0,5 – 10 sec
  • AC demagnetization by decreasing curve (cca 2 sec.)
  • duty cycle (intermitent) 30 %
  • manual/automatic process control
  • electropneumatic switching between lengthwise and circulary magnetization
  • 40 litres stainless steel reservoir, pump 390 VA, hand hose spraying
  • feeding 3 + PEN 400 V – 50 Hz, power consumption 100 kV

 

OPTION:
  • dark cabine, UV lamps, UV meters, Luxmeters, Gauss/Tesla meters, MTU gauges, Bertholds/ASTM gauges, centrifuge tubes
  • motorized coil and rotation
  • coils/tunnels for demagnetization, conveyors

 

CASP System – Your Partner in Non-Destructive Testing and Industrial Automation!
2002 - 2024 © Copyright CASP System / Privacy policy / Disclaimer / Contact